HVAC Products
Our latest versions of controls are fully BACnet compatible
making integration easier than ever before. The line of products
outlined to the left, coupled with our newest firmware and
front-end software, provide endless possibilities.
New features like advanced reporting, alarms and notifications to wireless handheld
devices and remote access via the Internet coupled with an easy to learn, easy
to use graphical user interface make Divcon EMS the right choice for your building
automation needs.
System Managers
Our latest versions of controls are fully BACnet compatible
making integration easier than ever before. The line of products
outlined to the left, coupled with our newest firmware and
front-end software, provide endless possibilities.
New features like advanced reporting, alarms and notifications to wireless handheld
devices and remote access via the Internet coupled with an easy to learn, easy
to use graphical user interface make Divcon EMS the right choice for your building
automation needs.
DSM-T0
The Delta Room Controller is a Native BACnet™ Application
Controller that communicates on an RS-485 LAN using the MS/TP
BACnet protocol.
The controller is housed in a stylized wall mounted housing and includes programmable
LCD and keypad functions, and supports the Delta BACstat.
Strategies are written in GCL, rather than residing in fixed algorithms. Both
firmware and controller databases are loadable over the network.
The DSM-TO features a LCD with keypad that can be used as a stand-alone interface
for a building network to set equipment schedules, adjust setpoint, and can be
used to adjust network time or application controllers.
DSM-050
The Delta™ DSM-050 is a Native BACnet™ Panel that
routes network traffic between BACnet IP WANS (Wide Area Networks),
Ethernet, BACnet MS/TP, and BACnet PTP LANS (Local Area
Network) using BACnet protocols.
The DSM-050 comes with an add-on 10Base-T Ethernet network card, one RS-485 Port,
two RS-232 ports, Real-Time Clock and Battery backup.
System Controllers
Our latest versions of controls are fully BACnet compatible
making integration easier than ever before. The line of products
outlined to the left, coupled with our newest firmware and
front-end software, provide endless possibilities.
New features like advanced reporting, alarms and notifications to wireless handheld
devices and remote access via the Internet coupled with an easy to learn, easy
to use graphical user interface make Divcon EMS the right choice for your building
automation needs.
DSC-1616
The Delta 16x16 Controller is a Native BACnet™ Controller
that communicates either on an RS-485 LAN using the MS/TP BACnet
protocol, or optionally over Twisted-Pair Ethernet (10BaseT).
It also supports an MS/TP SubLAN for VAV and other Application-based
Controllers. Alternatively, the SubLAN may be configured to support
up to 12 Delta BACstats and other Delta LINKnet™ I/O devices.
The controller is designed for a wide range of applications with
mid-sized I/O requirements, and strategies are written in Delta’s
powerful GCL programming language. Both firmware and controller
databases are loadable over the network.
DSC-1212
The Delta 12x12 Controller is a Native BACnet™ Controller
that communicates either on an RS-485 LAN using the MS/TP BACnet
protocol, or optionally over Twisted-Pair Ethernet (10BaseT
using BACnet/IP and BACnet over Ethernet). It also supports
an MS/TP SubLAN for VAV and other Application-based Controllers.
Alternatively, the SubLAN may be configured to support up to
12 Delta BACstats and other Delta LINKnet™ I/O devices.
The controller is designed for a wide range of applications
with mid-sized I/O requirements, and strategies are written
in Delta’s powerful GCL programming language. Both firmware
and controller databases are loadable over the network.
DSC-1280
The Delta™ 12x8 Controller is a Native BACnet™ Controller
that communicates either on an RS-485 LAN using the MS/TP BACnet
protocol, or optionally over Twisted-Pair Ethernet (10BaseT
using BACnet/IP and BACnet over Ethernet). It also supports
an MS/TP SubLAN for VAV and other Application-based Controllers.
Alternatively, the SubLAN may be configured to support up to
12 Delta BACstats and other Delta LINKnet™ I/O devices.
The controller is designed for a wide range of applications with mid-sized I/O
requirements, and strategies are written in Delta’s powerful GCL programming
language. Both firmware and controller databases are loadable over the network.
DSC-T305
The Delta Room Controller is a Native BACnet™ Application
Controller that communicates on an RS-485 LAN using the BACnet
MS/TP protocol.
The controller is housed within a stylized wall mounted housing and includes
programmable LCD and keypad functions, and supports the Delta BACstat. Strategies
are written in GCL, rather than residing in fixed algorithms.
Both firmware and controller databases are loadable over the network.
DSC-1616EX
The DSC-1616EX is a Native BACnet™ Controller
which is an assembly of the Delta Control Unit (DCU-050), the
I/O versatility of the Delta Base Input/Output Board (DBB-060)
and the PC/104 Ethernet Expansion Card (DXC-052-3). The controller
is housed within a stylized wall mounted housing and includes
programmable LCD and keypad functions, and supports the Delta
BACstat. Strategies are written in GCL, rather than residing
in fixed algorithms.
The pre-assembled DSC-1616EX is easy to install and the assembly can be expanded
with other components.
DBB-060
The Base I/O Board plugs beneath the Delta Control Unit (DCU)
to configure it as a high performance controller for direct
digital control of the various HVAC and other building services.
The Base I/O Board provides 16 universal inputs and 16 universal outputs that
are software configurable as digital or analog. Each universal input is provided
with a status indicating red LED. It is configured to the input signal type through
its associated input selector block located adjacent to the input. Active sensors
(e.g. 4-20 mA transducers) can additionally be powered from the 24 VDC terminal
located on the board (maximum total current draw of 200 mA dc).Universal outputs
supply 0-10 VDC to output devices connected at the output channel lower level
terminals (maximum current draw of 20 mA DC).
A Plug-In Module socket associated with each output allows each output channel
to be optionally configured with a Plug-In Module. Depending on the model type,
inserting a Plug-In Module can configure manual override capability for the output
channel by providing a switch and, if required, a positioning dial. At the same
time output status indication is provided via a green LED also located on the
module.
DPM-065xx
These series of Plug-In Modules
provide additional capabilities to the Base I/O Board and various
I/O Expansion Boards. The modules allow the Delta Control Unit
(DCU) and Base I/O to be tailored to specific applications.
The type of Plug-In Module used is ‘auto-sensed’ by
the Delta Control Unit (DCU) upon power up. Auto-sensing simplifies
setup.
The Plug-In Modules are powered by the Delta Control Unit (DCU) through the Base
I/O Board and provide their extra features to existing physical outputs on the
Base I/O Board or various Expansion Boards.
DEB-10xx
The 8 Input and 8 output I/O Expansion Board connect, in series,
to the base I/O Board (DBB-060) and increases the controller
I/O capability by adding an additional 16 points per board.
DXC-052-2
The PC/104 Ethernet Expansion Card plugs into the Delta Control
Unit and provides high speed peer-to-peer access between distributed
controllers over an industry standard Ethernet LAN at 10 million
bits/s.
DXC-052-3
The PC/104 Ethernet Expansion Card plugs into the Delta Control
Unit and provides high speed peerto-peer access between distributed
controllers over an industry standard Ethernet LAN at 10 million
bits/s.
Using Ethernet allows Delta panel communications to operate in existing or new
Ethernet networks. In addition, Ethernet can be configured as a wide area network
to provide a permanent high-speed connection to various remote sites being monitored
and controlled from a central OWS location.
An Ethernet network may also use fiber optic cable with appropriately installed
transceivers.
Application Controllers
Our latest versions of controls are fully BACnet compatible
making integration easier than ever before. The line of products
outlined to the left, coupled with our newest firmware and
front-end software, provide endless possibilities.
New features like advanced reporting, alarms and notifications to wireless handheld
devices and remote access via the Internet coupled with an easy to learn, easy
to use graphical user interface make Divcon EMS the right choice for your building
automation needs.
DAC-633
The Delta™ 6x6 Controller is a Native BACnet™ Application
Controller that communicates on an RS-485 LAN using the BACnet
MS/TP protocol.
The controller is designed for a wide range of applications
with small local I/O requirements and supports up to 4 Delta
BACstats™. Strategies are written
in Delta’s powerful GCL programming language.
Both firmware and controller databases are loadable over the network.
DAC-606
The Delta™ 6x6 Controller is a Native BACnet™ Application
Controller that communicates on an RS-485 LAN using the BACnet™ MS/TP
protocol.
The controller is designed for a wide range of applications with small local
I/O requirements and supports up to 4 BACstats™ (DNS-14, DNS-24).Strategies
are written in Delta’s powerful GCL programming language.
Both firmware and controller databases are loadable over the network.
DAC-V322; DAC-V304; DAC-322; DAC-304
The Delta
VAV Controller is a Native BACnet™ Application
Controller that communicates on an RS-485 LAN using the BACnet
MS/TP protocol.
The controller is specifically designed for VAV applications
and supports the Delta BACstat™.
Strategies are written in GCL rather than residing in fixed algorithms.
Both firmware and controller databases are loadable over the network. The damper
actuator assembly is available with or without position feedback. The additional
inputs and outputs can be configured for additional functions as required.
DAC-T305
The Delta VAV Controller is a Native
BACnet™ Application
Controller that communicates on an RS-485 LAN using the BACnet
MS/TP protocol.
The controller is housed within a stylized wall mounted housing
and includes programmable LCD and keypad functions, and supports
the Delta BACstat™.
Strategies are written in GCL rather than residing in fixed algorithms.
Both firmware and controller databases are loadable over the network.
Network Sensors
Our latest versions of controls are fully BACnet compatible
making integration easier than ever before. The line of products
outlined to the left, coupled with our newest firmware and
front-end software, provide endless possibilities.
New features like advanced reporting, alarms and notifications to wireless handheld
devices and remote access via the Internet coupled with an easy to learn, easy
to use graphical user interface make Divcon EMS the right choice for your building
automation needs.
DNT-T305
The Delta Room Controller is a Native BACnet™ Application
Controller that communicates on an RS-485 LAN using the BACnet
MS/TP protocol. The controller is housed within a stylized
wall mounted housing and includes programmable LCD and keypad
functions, and supports the Delta BACstat™.
Strategies are written in GCL, rather than reside in fixed algorithms.
Both firmware and controller databases are loadable over the network.
DNT-T221
The DNT-T221 BACStat II™ is an intelligent room sensor
with a custom 3-value, 96 segment, LCD display that is used
with Delta’s BACnet™ Application Controllers which
are capable of communicating on Delta’s proprietary LINKnet™ network
or directly on a BACnet MS/TP network.
When connected to an Application Controller on a LINKnet network it provides
programmable remote sensor and expanded I/O capabilities to the controller. When
connected on the MS/TP network, it functions as an independent BACnet sensor
device.
DNT-T103
The DNT-T103 BACStat II™ is an intelligent room sensor
with a custom 3-value, 96 segment, LCDdisplay that is used
with Delta’s BACnet™ Application Controllers which
are capable of communicating on Delta’s proprietary LINKnet™ network
or directly on a BACnet MS/TP network.
It is capable of displaying a wide range of digital or analog values, including
setpoints, temperature, air flow, heating and cooling status, fan speed, valve
and damper position and more.
When connected to an Application Controller on a LINKnet network it provides
programmable remote sensor and expanded I/O capabilities to the controller. When
connected on the MS/TP network, it functions as an independent BACnet sensor
device.
Field Modules
Our latest versions of controls are fully BACnet compatible
making integration easier than ever before. The line of products
outlined to the left, coupled with our newest firmware and
front-end software, provide endless possibilities.
New features like advanced reporting, alarms and notifications to wireless handheld
devices and remote access via the Internet coupled with an easy to learn, easy
to use graphical user interface make Divcon EMS the right choice for your building
automation needs.
DFM-200, 202, 220
The Delta Field Modules are small expansion I/O boards that
provide remotely expandable I/O to Delta’s BACnet™ Controllers.
The DFM-2xx Field Modules provide two universal inputs in three
different output configurations, and is capable of communicating
on Delta’s proprietary LINKnet™ network or directly
on an RS-485 MS/TP network (DFM-200 model only).
When connected to a LINKnet network it provides remote input and programmable
output capabilities to the controller. When connected on the MS/TP network it
functions as an independent BACnet device with inputs that can be accessed over
the MS/TP network.
DFM-400, 404, 440
Delta Field Modules are
small expansion I/O boards that provide remotely expandable
I/O to Delta’s BACnet™ Controllers.
The DFM-4xx Field Modules provide four universal inputs in three different output
configurations, and is capable of communicating on Delta’s proprietary
LINKnet™ network or directly on an RS-485 MS/TP network (DFM-400 model
only).
When connected to a Controller on a LINKnet network it provides remote input
and programmable output capabilities to the controller. When connected on the
MS/TP network it functions as an independent BACnet device with inputs that can
be accessed over the MS/TP network.
DFM-1600
Delta Field Modules are small expansion
I/O boards that provide remotely expandable I/O to Delta’s
BACnet™ Controllers.
The DFM-1600 provides expandable remote I/O to Delta’s BACnet System Controllers
(DSCs). This field module provides 16 universal inputs and communicates on Delta’s
LINKnet network. When connected to a LINKnet network, the DFM-1600 provides programmable
remote input capabilities to its connected controller.
|